1 Introduction

Expert humans use flowJo software to manually gate FCS data files either individually or by setting a static gate to apply on all the files. The former is very tedious specially when there is a large number of files and the cost for the latter is to ignore characteristics of individual samples.

flowDensity is a supervised clustering algorithm based on density estimation techniques designed specifically to overcome these problems. It automates the current practice of manual 2D gating and adjusts the gates for each FCS data file individually.

Although automated flow cytometry methods developed to date have focused on fully automated analysis which is especially suited for discovery, they seldom match manual results where this is desirable (e.g., for diagnosis). In contrast, flowDensity aims to gate predefined cell populations of interest where the gating strategy, i.e., sequence of gates, is known. This helps it take advantage of expert knowledge and as a result it often matches manual results very well. In addition, since flowDensity uses only two dimensions at a time, it is very fast and requires mush less computational power.

2 How to use flowDensity?

In order to use flowDensity, the gating strategy is required. A gating strategy here means the sequence of 2D gates needed to apply one at a time on a FCS file to eventually extract the cell subset of interest.

A 2D gate consists of two channels (dimensions) or equivalently a phenotype with two markers. In addition, the corresponding expression level for each channel is given. For example, phenotype CD19+CD20- has markers CD19 and CD20 with expression values positive and negative, respectively.

To use flowDensity, this 2D gate is input to the function flowDensity(.). The channels in the gate are used for the channels argument and the expression values are used for the position argument of the function.

Let assume for example that CD19 is on channel PerCP-Cy5-5-A and CD20 is on channel APC-H7-A. Therefore, the corresponding input arguments are:

channels=c("PerCP-Cy5-5-A", "APC-H7-A") and position=c(TRUE,FALSE).

In general, channels argument can be set using either names of the channels or their corresponding indices (column numbers in the FCS file) and position argument could be one of the four logical pairs (TRUE,FALSE), (FALSE,TRUE), (FALSE,FALSE) and (TRUE,TRUE). If the user needs to set the thresholds for only one of the channels, then position for the other channel must be set to NA.

In addition to the above arguments, cell.population, gatingHierarchy or flow.frame argument is required where the former is an object of class CellPopulation loaded from flowDensity namespace and the latter is a flowFrame object loaded from flowCore namespace. It is also possible to provide the polygon filter. In this case position can be set to anything, and the filter should be a data.frame or matrix where the columns match with the FCS file channels.

3 Examples

In this section we present several examples to elaborate how to use the flowDensity(.) function.

3.1 Extracting Bcell

This example shows how to use flowDensity to extract B cells by using the gating strategy Singlet/viability-CD3-/CD19+CD20+ or equivalently singlets/Bcell.

library(flowCore)
library(flowDensity)
## Warning: replacing previous import 'flowCore::plot' by 'graphics::plot' when
## loading 'flowDensity'
data_dir <- system.file("extdata", package = "flowDensity")
load(list.files(pattern = 'sampleFCS_1', data_dir, full = TRUE))
f
## flowFrame object ''
## with 23000 cells and 13 observables:
##             name        desc     range    minRange  maxRange
## $P1        FSC-A          NA    262144 -111.000000  262143.0
## $P2        FSC-H          NA    262144    0.000000  262143.0
## $P3        SSC-A          NA    262144 -111.000000  262143.0
## $P4        SSC-H          NA    262144    0.000000  262143.0
## $P5        APC-A        CD38    262144   -0.044968       4.5
## ...          ...         ...       ...         ...       ...
## $P9       V450-A         CD3    262144   0.1590741       4.5
## $P10      V500-A         IgD    262144   0.2276837       4.5
## $P11        PE-A        CD24    262144  -0.0510186       4.5
## $P12    PE-Cy7-A        CD27    262144  -0.2319877       4.5
## $P13        Time          NA    262144   0.0000000  262143.0
## 211 keywords are stored in the 'description' slot
sngl <- flowDensity(f,channels = c("FSC-A","FSC-H"),position = c(F,F),
                    percentile =c(.99999,.99999),use.percentile = c(T,T),
                    ellip.gate = T,scale = .99 )
plotDens(f,c(1,2))
lines(sngl@filter,type="l")

plot function in flowDensity can also be used to show the population, gates, counts, and densities of channels. ts arguments are a flowFrame object and an object of class CellPopulation.

plot(f,sngl)

3.2 Gating rare cell populations

To emulate the practice of expert humans for identification of high, flowDensity provides two parameters that help fine tune the algorithm for identification of small cell populations. These parameters are set by providing following arguments in the flowDensity(.) function:

  • upper: This argument is used to identify small cell subsets present at the tail or head of the density distribution curve where they are typically camouflaged due to the presence of adjacent large cell populations. If it is set to TRUE (FALS), flowDensity checks the tail (head) of the density distribution. If it is required to use upper for one channel and not the other, the NA value should be used; for example upper=c(FALSE,NA).
  • use.upper: This argument is only used when the user wants to force the algorithm to use the upper argument no matter how many peaks are found in the density distribution.
  • percentile: This argument gets a value of \([0,1)\) and provides the ability to set a threshold based on the percentile of the density distribution. To force using this threshold, argument use.percentile should be set to TRUE, otherwise the percentile threshold will be automatically used when appropriate.
  • bi.modal: This arguments can be set, when there are more than two populations. It tries to split the data into half when possible.

For example, we can use flowDensity to extract plasmablasts cell population as follows:

data_dir <- system.file("extdata", package = "flowDensity")
load(list.files(pattern = 'sampleFCS_1', data_dir, full = TRUE))
#bcell <- flowDensity(f,channels = c(4,9),position = c(NA,T))
CD19pCD20n <- flowDensity(obj=f, channels=c(8, 6),
                        position=c(T,F))
plasmablasts <- flowDensity(obj=CD19pCD20n, channels=c(5, 12),
                            position=c(T, T))
plotDens(CD19pCD20n@flow.frame, plasmablasts@channels, pch=19)
points(plasmablasts@filter, type='l', col=2, lwd=2)

To overcome this problem, flowDensity tracks the slope of the curve of the density distribution by comparing the slope of a window of points on the curve with specific length to examine if it drops below a a threshold relative to the adjacent windows. This way, once the large cell subset ends and the rare one starts the dramatic change in the slope can be detected by flowDensity and the threshold is set. We call this technique as trackSlope.

In seldom cases the slope varies slowly and smoothly so that no relatively huge change is sensed by this technique. If such, the \(90^{th}\) percentile is used as a gate. A rule of thumb is that if the spread of the density distribution is mostly around the mean, i.e., the standard deviation is small relative to the mean, then most likely the trackSlope returns better results than \(90^{th}\). If neither of these techniques are bale to set a proper threshold, the peak value plus a multiplier of the standard deviation is chosen as the threshold.

flowDensity is able to decide on which of these methods to use. However, the user can also modify this decision by setting certain parameters specifically for tricky cell populations.

In the Figure above flowDensity has been used to gate Plasma blasts cell population which is a rare cell subset of CD3+CD19+CD20- cell population. On the \(x\)-axis for the marker CD38 the trackSlope technique is used whereas on the \(y\)-axis for the marker CD27 HLA-DR the peak plus \(1.5\times\)standard deviation gives a proper gate. Note that the multiplier 1.5 is the default value of the algorithm. However, it can be both set by user or set via analyzing the density distribution by flowDensity.

3.3 Multiple calls for a single cell population identification

flowDensity can be used recursively to gate a cell population of interest. In the example below flowDensity has been used to gate ``lymphocytes’’ from CD45 vs SSC. In order to gate lymphocytes more accurate and tighter, flowDensity can be called several times. First time it finds the thresholds for both channels, then returns SSC-CD45+ as an input for the second call. In the last call thresholds of CD45 from the first call and thresholds of SSC from the second call is given to flowDensity to draw ellipse around the lymphocyte population. In some cases CD45 has only one peak so the percentile of 0.25 is given to flowDensity to detect the right population. For SSC 0.85 would give the optimum threshold.

library(flowCore)
library(flowDensity)
data_dir <- system.file("extdata", package = "flowDensity")
load(list.files(pattern = 'sampleFCS_2', data_dir, full = TRUE))
f2
## flowFrame object ''
## with 7000 cells and 14 observables:
##             name        desc     range   minRange  maxRange
## $P1        FSC-A          NA    262144          0    262143
## $P2        FSC-H          NA    262144          0    262143
## $P3        FSC-W          NA    262144          0    262143
## $P4        SSC-A          NA    262144          0    262143
## $P5        SSC-H          NA    262144          0    262143
## ...          ...         ...       ...        ...       ...
## $P10    PE-Cy7-A        CD10    262144  0.8315758       4.5
## $P11       APC-A        CD19    262144  0.4939999       4.5
## $P12    APC-H7-A        CD20    262144  0.6968035       4.5
## $P13      V450-A        CD38    262144  0.3761896       4.5
## $P14      V500-A        CD45    262144 -0.0272588       4.5
## 204 keywords are stored in the 'description' slot
channels <- c("V500-A", "SSC-A")
# First call to flowDensity
tmp.cp1 <- flowDensity(obj=f2, channels=channels,
                      position=c(TRUE, FALSE), percentile=c(0.25, NA))
# Second call to flowDensity
tmp.cp2 <- flowDensity(obj=tmp.cp1, channels=channels,
                       position=c(TRUE, FALSE), gates=c(FALSE, NA), 
                       percentile=c(NA, 0.85))
# Final call to flowDensity
lymph <- flowDensity(obj=f2, channels=channels,
                     position=c(TRUE, FALSE), gates=c(tmp.cp1@gates[1], 
                     tmp.cp2@gates[2]), ellip.gate=TRUE, scale=.99)

plot(f2, tmp.cp1)

plot(f2, tmp.cp2)

par(mfrow=c(1,1))
plotDens(f2, channels=channels,axes=T)
lines(lymph@filter, type="l", col=2, lwd=2)
legend("topleft",legend = paste0("count: ",lymph@cell.count),bty = "n")

It is possible to extract the flowFrame object from CellPopulation, by getflowFrame() function.

getflowFrame(lymph)
## flowFrame object ''
## with 3125 cells and 14 observables:
##             name        desc     range   minRange  maxRange
## $P1        FSC-A          NA    262144          0    262143
## $P2        FSC-H          NA    262144          0    262143
## $P3        FSC-W          NA    262144          0    262143
## $P4        SSC-A          NA    262144          0    262143
## $P5        SSC-H          NA    262144          0    262143
## ...          ...         ...       ...        ...       ...
## $P10    PE-Cy7-A        CD10    262144  0.8315758       4.5
## $P11       APC-A        CD19    262144  0.4939999       4.5
## $P12    APC-H7-A        CD20    262144  0.6968035       4.5
## $P13      V450-A        CD38    262144  0.3761896       4.5
## $P14      V500-A        CD45    262144 -0.0272588       4.5
## 204 keywords are stored in the 'description' slot

3.3.1 Gating cells using a control sample

To utilize matched control samples (e.g. FMO controls), the `flowDensity(.) function has parameters that allow control data to be included. When this option is used, the gating threshold is calculated in the control data and applied to the stimulated data. Control samples are added using two parameters:

  • use.control: When set to TRUE, flowDensity uses matched control data to calculate gating thresholds. This argument can be set for both channels. For example: `use.control=c(TRUE, FALSE)}.
  • control: This argument accepts flowFrame or CellPopulation objects containing control data matched to the specified stimulated data (passed in the obj argument). Control samples can be included for one or both of the channels. If no control is to be used, the argument should be passed an NA value (default). For example, if the first channel should be gated using a control but the second channel should be gated normally (using the stimulated data), the user would specify control=c(fmo.data, NA).

When control data is used, the other gating arguments (upper, percentile, n.sd, etc.) are applied to finding the threshold in the control sample instead of the stimulated sample.

For example, an FMO control (i.e. negative control) for the BV421-A channel can be used for gating as follows:

load(list.files(pattern = 'sampleFCS_3.Rdata', data_dir, full = TRUE))
f3
## flowFrame object ''
## with 8000 cells and 20 observables:
##             name        desc     range  minRange  maxRange
## $P1        FSC-A          NA    262144   0.00000  262143.0
## $P2        FSC-W          NA    262144   0.00000  262143.0
## $P3        SSC-A          NA    262144   0.00000  262143.0
## $P4        SSC-W          NA    262144   0.00000  262143.0
## $P5        APC-A          NA    262144   1.42462       4.5
## ...          ...         ...       ...       ...       ...
## $P16     BV785-A          NA    262144  1.240968       4.5
## $P17        PE-A          NA    262144  0.156358       4.5
## $P18    PE-Cy5-A          NA    262144  0.736939       4.5
## $P19    PE-Cy7-A          NA    262144  0.512481       4.5
## $P20        Time          NA    262144  0.000000  262143.0
## 269 keywords are stored in the 'description' slot
load(list.files(pattern = 'sampleFCS_3_FMO', data_dir, full = TRUE))
f3.fmo
## flowFrame object ''
## with 8000 cells and 20 observables:
##             name        desc     range  minRange  maxRange
## $P1        FSC-A          NA    262144   0.00000  262143.0
## $P2        FSC-W          NA    262144   0.00000  262143.0
## $P3        SSC-A          NA    262144   0.00000  262143.0
## $P4        SSC-W          NA    262144   0.00000  262143.0
## $P5        APC-A          NA    262144   1.42462       4.5
## ...          ...         ...       ...       ...       ...
## $P16     BV785-A          NA    262144  1.240968       4.5
## $P17        PE-A          NA    262144  0.156358       4.5
## $P18    PE-Cy5-A          NA    262144  0.736939       4.5
## $P19    PE-Cy7-A          NA    262144  0.512481       4.5
## $P20        Time          NA    262144  0.000000  262143.0
## 269 keywords are stored in the 'description' slot
f3.gated <- flowDensity(obj=f3, channels=c('BV421-A', 'FSC-A'),
                        position = c(TRUE, NA),use.control = c(TRUE, F)
                        , control = c(f3.fmo, NA),verbose=F)
f3.fmo.gated <- flowDensity(obj=f3.fmo, channels=c('BV421-A', 'FSC-A'),
                            position=c(TRUE, NA),
                            gates=c(f3.gated@gates[1], NA),verbose=F)
plot(f3.fmo, f3.fmo.gated)

plot(f3, f3.gated)

When only one peak is present in density, flowDensity prints out a message that can be suppressed by verbose=FALSE for each of the marker. This message prints out how cutoff was calculated based on the present arguments (percentile, upper, sd.threshold). For finer control, additional gating arguments can be passed that will be applied to the control sample. For example, the below example will gate using the 98-th percentile in control data:

f3.gated.98p <- flowDensity(obj=f3, channels=c('BV421-A', 'FSC-A'),
                            position = c(TRUE, NA),use.percentile = c(TRUE, NA),
                            percentile = 0.98, use.control = c(TRUE, FALSE),
                            control = c(f3.fmo, NA))
f3.fmo.gated.98p <- flowDensity(obj=f3.fmo, channels=c('BV421-A', 'FSC-A'),
                                position = c(TRUE, NA),
                                gates=c(f3.gated.98p@gates[1], NA))
plot(f3.fmo, f3.fmo.gated.98p)

plot(f3, f3.gated.98p)

Note: When using controls, setting position=TRUE will treat the data as a negative control and extract the population above the threshold. Setting position=FALSE will treat it as a positive control.

3.4 Selecting threshold using deGate()

Another option beside flowDensity is deGate() function, which gives better control over cutoffs. The output is either a number or a vector of all possible cutoffs if all.cuts=T. In the example below, some of the possibilities are provided.

load(list.files(pattern = 'sampleFCS_2', data_dir, full = TRUE))
thresholds <- deGate(obj = f2,channel = 9)
#Percentile default is .95, which can be changed
thresholds.prcnt <- deGate(f2,channel = 9,use.percentile=T,percentile=.3) 
thresholds.lo <- deGate(f2,channel = 9,use.upper=T,upper=F,alpha = .9)
thresholds.hi <- deGate(f2,channel = 9,use.upper=T,upper=T,alpha = .9)

plotDens(f2,c(9,12))
abline(v=c(thresholds,thresholds.prcnt,thresholds.lo,thresholds.hi),col=c(1,2,3,4))

3.5 Gating using notSubFrame

Sometimes user would like to remove a population, and continue the gating sequence. This is possible using notSubFrame.

cd19.gate <- deGate(f, channel = 8)
cd20.gate <- deGate(f,channel = 9)
cd20.neg <- notSubFrame(f, channels = c(8,9),position = c(F,F),gates=c(cd19.gate,cd20.gate))
plotDens(f,c(8,9),axes=T)
lines(cd20.neg@filter, type="l")

plotDens(cd20.neg,c(8,9),main="Not CD19-CD20-")

4 Latest update features

Multiple arguments have been added to deGate, and plotDens, please check the man page for these functions. Some of these arguments are:

  • after.peak: When TRUE, it returns a cutoff that is after the maximum peaks.

  • bimodal: When TRUE, it returns a cutoff that is after the maximum peaks.

  • slope.w: Sets window.width for tracking the slope, when there is only one peak.

  • count.lim: Minimum limit for events count in order to calculate the threshold. Default is 20.

  • density.overlay: When c(TRUE,TRUE), it overlays density curves over the dot plot.

4.1 Peak extraction

Function getPeaks returns all the peaks in a specified channel of flowFrame. It also takes a vector or density object as input.

load(list.files(pattern = 'sampleFCS_2', data_dir, full = TRUE))
getPeaks(f2,channel = 9)
## $Peaks
## [1] 1.159812 3.284403
## 
## $P.ind
## [1] 167 364
## 
## $P.h
## [1] 0.6162759 0.4872584

You can specify the sensitivity of both getPeaks and deGate for small peaks, and twin peaks (peaks that are fairly close, and similar in height and their corresponding valleys). This can be done by tinypeak.removal and twin.factor. See ?deGate() for more detail.

4.2 Density overlay

It is possible to overlay density curves over the bi-axial plot, using plotDens function.

load(list.files(pattern = 'sampleFCS_2', data_dir, full = TRUE))

plotDens(f2, channels = c(9,12),density.overlay = c(T,T))

5 Licensing

Under the Artistic License, you are free to use and redistribute this software.